O'Keeffe's, Inc. - Access Ladders, Skylights, and Fire-Rated Glass
ProductsCompanyContact usLinks / ArticlesProjects
  Reglets : TOP   Type EN: Existing / New Surface Mount
 
Types
    Type MI:
Masonry Install
    Tyoe CF:
Concrete with
Fastening Block
    Type SS:
Stucco or Siding
  Type EN:
Existing / New
Surface Mount
    Type CW:
Concrete Wall
   
Flashing Types & Materials
Flashing Finishes
Accessories
Reglet Specifications
   
 

Material:
Extruded Noryl®

Description:
The type EN is for surface mounting onto existing or new construction. Continuous groves in the reglet allow effective field application of tape and sealant. The wedge gasket is removable for re-roofing.

Flashing for Reglet Type EN:
Use flashing type 2 or 3.

Installation:
Secure reglet to the existing (or new) wall with appropriate fasteners 16 inches on center (fasteners by others). Precisely align abutting sections. Bed reglet splice sleeves in sealant. Miter all corners. Apply sealant according to manufacturer’s recommendations. Secure flashing to reglet with EPDM wedge gasket. Overlap flashing 3 inches. Use wind clips as needed. Flashing can be taken out for re-roofing and reinstalled.


 

 