Material:
Extruded Noryl®
Description:
The type CF reglet is designed to be embedded vertically or horizontally
into concrete. It provides a continuous fastening block to attach
the roofing membrane. A removable strip prevents the reglet opening
from filling with concrete during pouring. The wedge gasket is
removable
for re-roofing.
For Vertical Applications
Flashing for Reglet Type CF: Use flashing
type 4.
Installation: Before pouring concrete fasten reglet to forms
16 inches on center (fasteners by others). Precisely align abutting
sections. Miter all corners. After forms are taken down, remove
filler strip and clip off fasteners. Attach roofing membrane according
to the manufacturers recommendations. Secure flashing to reglet
with EPDM wedge gasket. Overlap flashing 3 inches. Use wind clips
as needed. Flashing can be taken out for re-roofing and reinstalled.
For Horizontal Applications
Flashing for Reglet Type CF: Use flashing type 5.
Installation: Before pouring concrete use steel mounting
straps to position reglet flush with the top surface of the pour.
Precisely align abutting sections. Miter all corners. After forms
are taken down, remove filler strip and clip off fasteners. Install
insulation. Secure flashing to reglet with sealant per the manufacturers
instructions. Overlap flashing 3 inches. Flashing can be taken out
for re-roofing and reinstalled.
|